Model |
K7L___-B |
K8AK-LS |
Type |
Leakage sensor |
Conductive Level Controller |
|
|
|
Features |
• Detects leakage of water and chemicals with low conductivity
• Compact Plug-In units for use with Push-In Plus Terminal Block Sockets
• Models for long-distance wiring upto 400 m
• Ribbon Electrode Bands and Point Sensors available
• Sensor disconnect function available on some models |
• Outputs can be set to self-hold at ON or OFF using self-holding circuits.
• Sensitivity adjustment of operating resistance from 10 to 100k Ohms for application to a wide range of liquids
• Delay timer to prevent relay contact chattering caused by waves |
Supply voltage |
12 to 24V DC |
24 VAC, 50/60 Hz, or 24 VDC
100 to 240 VAC, 50/60 Hz |
Detectable substances |
Liquids with resistance up to 50M Ohms |
Conductive liquids |
Control output |
NPN open collector; 100mA at 30 VDC |
6 A at 250 VAC for resistive load
1 A at 250 VAC for inductive load |
|
|
|
Model |
K7L-AT50 and K7L-U |
61F-N, 61F-G_N, 61F-GP, 61F-GPN
and 61F-GP-N2 |
Type |
Leakage sensor |
Floatless level controller |
|
|
|
Features |
• Detects leakage of water and chemicals
• Space saving sensor amplifier
• Socket-mounted design |
• Floatless conductive system
• Separate probes for high, low and alarm levels |
Supply voltage |
12 to 24V DC |
24 or 240V AC |
Detectable substances |
Liquids with resistance up to 50M Ohms |
Conductive liquids |
Control output |
NPN open collector; 100mA at 30 VDC |
Relay; 5A at 250VAC |
|
|
|
Model |
61F-WLA / 61F-GPN-V50 |
|
Type |
Water leak alarm and Detector |
|
|
|
|
Features |
• Settable operating resistance, to detect desired leakage levels
• Uses corrosive resistive sensing band
• Socket-mounted design |
|
Supply voltage |
24, 110-120 or 220-240V AC |
|
Detectable substances |
Liquids with resistance up to 50K Ohms |
|
Control output |
3 A at 250 VAC for resistive load
1 A at 250 VAC for inductive load |
|